
Sound and Vibration Instrument Hire and Calibration
Architectural and Building Acoustics Equipment Hire

Instruments for all Sound Insulation and Building Acoustics measurements, including RASTI and STIPA Meters for Speech Transmission Index and Speech Intelligibility assessments .
We also stock Reverberation Time Meters, Noise Generators, Speaker / amplifiers and Impact Machines, all available individually or in kits with all the accessories and software for fully automated measurements in accordance with the Building Regulations and all the relevant British & International Standards.
B&K 2250 : Building and Room Acoustics Analyser | £ 37 a day * |
---|

The Bruel & Kjaer 2250 Sound Analyser with a BZ 7228 Sound Insulation module includes a noise generator and all the necessary software for one person to make Sound Insulation measurements in accordance with BS EN ISO 140 and other Building Acoustics Standards
Customer choices include:B&K 2260D : Building Acoustics Analyser | £ 37 a day * |
---|

Bruel & Kjaer 2260 Investigator with the BZ 7204 Sound Insulation module includes all the necessary software to make measurements in accordance with the relevant British and International Standards
Hire options include:-B&K 2260E : Sound Intensity Analyser | £ 42 a day * |
---|

Hand-held 2260 meter with the BZ 7205 intensity software.
The combination of 2260E and the 3595 Sound Intensity Probe Kit enables :-
Flanking and Leak Detection investigations as well as
Sound Intensity measurements of Sound Reduction Index to BS EN ISO 717-1.
B&K 2250 RT : Reverberation Time Meter - with BZ 7227 software | £ 32 a day * |
---|

The Reverberation Time Software BZ-7227 enables the B&K 2250 to make Reverberation Time (RT) measurements.
Press the Start button, clap your hands and that's all it takes to do a basic measurement in small rooms. The traffic lights shows measurement status at a glance, and the resulting RT spectrum is shown as well as the average RT, reverberation time for the room. Alternatively for large spaces use the built-in noise generator plus an amplifier speaker system.
Keep track of measurement positions in the colour map display, check the indicators for measurement quality, and add spoken or text comments to positions or projects.
Measurements comply with the relevant parts of BS EN ISO 3382 and other Standards.
B&K 2250 Reverberation Time - details
B&K 3207 : Noise Impact Tapping Machine | £ 15 a day * |
---|

A 'foot steps' impact noise generator, for Impact Insulation Measurements to national and international standards
BS EN ISO 140 and BS EN ISO 717
For hire as stand alone instrument or part of a Building Acoustics Kit
B&K 3207 Impact Noise Machine - details.
B&K 3361 : RASTI - Speech Transmission Meter | £ 24 a day * |
---|

The Bruel & Kjaer 3361 measures RASTI and related parameters directly.
RASTI - Rapid Speech Transmission Index is a method for measuring speech intelligibility - for example in a lecture hall or over any public address system. The 3361 has two components:-
Nor 118+ : Building Acoustics Analyser - single channel | £ 32 a day * |
---|

Norsonic single channel acoustic testing and room acoustics analyser with internal noise generator and RT calculator - ideal for survey work. ***
Acoustic Insulation Ratings are made using the results and the tables in the relevant Standard(s). ***
We supply complete kits, or just order a noise output cable so you can use your own amplifiers, speakers etc., and add a tapping machine, sound impact if required.
Nor 118+ details + Building Acoustics Insulation Kits
*** For fully automated systems see the B&K 2250 or 2260D systems above.
Nor 213 : Norsonic Dodecahedron Speakers | £ 12 a day* |
---|

The sound power levels stated are when used with a Nor 260 or Nor 280 power amplifiers which also include a white and pink noise generator.
The Nor 223 version has been withdrawn.
Nor 250 : Norsonic Dodecahedron Speaker - 120 dB | £ 10 a day * |
---|

Portable 200 W, 120 dB SWL noise radiator with omnidirectional characteristics in accordance with BS EN ISO 140, when mounted on a hard reflecting surface.
Matched for continuous sound power levels up to 120 dB in the range 50 Hz to 5000 Hz when used with a Nor 260 or Nor 280 power amplifier / noise generator
Nor 250 Dodecahedron Speakers - detailsNor 260 : Norsonic Noise Generator and Power Amplifier | £ 10 a day * |
---|

Power amplifier with internal pink and white noise generator.
Ideal for use with a Nor 250 hemi-dodecahedron or the Nor 213 full dodecahedron speakers and output sound power levels of up to 120 dB. Mains operated.Output - 250 W continuous or 1 kW peak into 4 Ω load
Nor 260 Noise Generator / Power Amplifier - detailsNor 280 : Noise Generator and Power Amplifier | £ 12 a day * |
---|

Power amplifier with internal pink and white noise generator.
Ideal for use with a Nor 250 hemi-dodecahedron or the Nor 213 dodecahedron speakers for output sound power levels of up to 120 dB. Mains operated.Output - 500 W rms into 4 Ω load
Nor 280 Noise Generator / Power Amplifier - detailsNor 840 : Sound Intensity and Building Acoustics Analyser |
---|
Withdrawn, the following details for information only.

Single and multi spectra measurements
Octave, 1/3, 1/12 and 1/24-octave + FFT
A : B : C, Linear, human vibration plus user defined networks.
0.1 Hz to 20 kHz frequency range in both channels
Time constants selectable from 1/16 seconds
Acoustic Insulation software built-in.
Nor 840 Building Acoustics Analyser - details
Sound Intensity software is also built in - add the GRAS 50AI intensity probe - if required.
NTi XL2 : Reverberation Time Analyser | £ 25 a day * |
---|

The NTi XL2 measures the RT60 Reverberation Time from 63 Hz to 8 KHz using the Schroeder method.
There are two modes of operation:NTi XL2 : STIPA - Speech Intelligibility Meter | £ 29 a day * |
---|

STIPA Measurements with XL2 Analyser : the analyser measures the speech intelligibility according to the latest revision of standard BS EN 60268-16:2011, current and older editions. It includes ambient noise correction and automated averaging of measurements.
The XL2 displays the measurement results as STI or as CIS results, accompanied by the individual levels and modulation indices of the seven octave bands.
NTi XL2 STIPA - speech intelligibility, meter and kit details
Click here to see our range of acoustic insulation testing kits.
* Our standard hire charges are based on a 4-day minimum period, details other options