Sound and Vibration Instrument Hire and Calibration
Casella CEL 350 Noise Dosimeter Specifications

CEL 350 : Personal Noise Dosimeter, dBadge, Sound Exposure Meter | £ 10 a day * |
---|
CEL 352 : Personal Noise Dosimeter, dBadge, Sound Exposure Meter | £ 10 a day * |
---|
Standards :
BS EN 61252 Personal Sound Exposure Meters
ANSI Si.25 Personal Noise Dosimeters
Measured Parameters ISO :
LAeq, LCpeak, LEP,d, Pa2Hours, Projected %dose (Q=3)Measured Parameters OSHA :
Lavg (Q=5), LZpeak, LASmax, %dose (Q=5), TWA Projected % dose (Q=5)Measured Parameters General :
LAFmax, LAFmin, LASminMeasured Parameters - 352 version :
LCeq - LAeqMeasured Parameters via dB35 :
LAIeq, LAImax, LAImin, LApeakMeasured Parameters Time History :
LAeq, LZpeak, LCpeak, LAavg (Q=5) stored as 1 minute valuesLinear Operating Range :
65.0 to 140.3 dB RMSPeak Measurement Range :
95.0 to 143.3 dB RMSFrequency Weighting RMS :
AFrequency Weighting PEAK :
C, A, Z (Linear)Time Weighting :
Slow, Fast and ImpulseAmplitude Weighting :
Q = 3 and Q = 5Selectable Thresholds :
2(70 to 90 dB), selectable in 1 dB stepsSelectable Criterion :
1(70 to 90 dB), selectable in 1 dB stepsMemory Capacity :
64 kB (180 Hours of measurements)Default Modes :
ISO or OSHACalibration Information :
Calibration dates, times and levelsSecurity :
Lock via keysPower Supply :
Internal NiMH cellsBattery Life :
32 Hours run capacitySize mm (in) :
72 x 47 x 52 (2.81 x 1.8 x 2.0) including windshieldWeight g (oz):
68 (2.4)Data Storage :
Non-volatile, 10 years of storageDisplay :
Graphic LCD 96 x 26 pixelsOutput (PC) :
Infrared download cable (supplied) to dB35 software* Our standard hire charges are based on a 4-day minimum period, details other options.